Your position: Home / CURRENT TRANSFORMER

DP Series Split core current transformer

001005
DP range of split core current transformers have been designed to easily fit around cables without breaking thecircuit.Its advantages of big capacity and big mounting hole size,could be used in more power applications.
Price:
  • TYPE:
    DP-23
    DP-58
    DP-88
    DP-812
    DP-816
  • RATIO:
    100/5A
    150/5A
    200/5A
    250/5A
    300/5A
    400/5A
    500/5A
    600/5A
    750/5A
    800/5A
    1000/5A
    1200/5A
    1250/5A
    1500/5A
    2000/5A
    2500/5A
    3000/5A
    4000/5A
    5000/5A
    6000/5A
Quantity:
-
+
(210000 available)
Please select the information you wantX
  • Description
  • Reviews

DP range of split core current transformers have been designed to easily fit around cables without breaking the

circuit.Its advantages of big capacity and big mounting hole size,could be used in more power applications.DP was

global used in most power applications.                                                                                                                                                                                                          Circuit connection diagram

  

 

Feature:

1:Double-screw fastening, safe, easy to install, portable.

2:Two built in fixing methods:Base;Busbar mounting
3:Wide inner window, allowing clamping of big cables or bus-bars.
4:Wide range of sizes to accommodate all the existing installations.
5:Primary current from 5A to 5000A.

 

 

 

Advantage:

1: Current measurement, monitoring and protection for electrical wiring and equipment.

2: Current and power measurement for electric motors, lighting, air compressor, heating

and ventilation system, air-condition equipment and automation - control system.

3: Current, power and energy monitoring device.

4: Relay protection device.

 

STANDARD:
IEC6044-1, EN60044-1, VDE0414-44-1, GB1208-2006

Technique Index:

 

Electrical Parameter Mechanical Parameter
Frequency 50-400Hz Case PC/UL94-V0
Rated Input 5A-5000A Bobbin PBT
Measuring range 10%In-120%In Core Silicon steel
Rated Output 0-5A Internal structure Epoxy
Ratio ≤ ± 0.5% Construction Tie
Phase angle ≤ ±30min Operation Temp -25oC~+75oC
Dielectric strangth 2.5KV/1mA/1min Operating Humidity ≤85%
Insulation Resistance DC500V/100MΩ min Output Connection Terminal
 

 

Dimension of case (mm):

 

Product MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1.0
DP-23 100/5A / 2.5VA 50/60Hz
150/5A / 2.5VA 50/60Hz
200/5A 2.5VA 5VA 50/60Hz
250/5A 2.5VA 5VA 50/60Hz
300/5A 5VA 5VA 50/60Hz
400/5A 5VA 5VA 50/60Hz
 
Product MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1.0
DP-58 250/5A / 2.5VA 50/60Hz
300/5A / 2.5VA 50/60Hz
400/5A 2.5VA 2.5VA 50/60Hz
500/5A 2.5VA 5VA 50/60Hz
600/5A 2.5VA 5VA 50/60Hz
800/5A 5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
 
Product MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1.0
DP-88 250/5A / 2.5VA 50/60Hz
300/5A / 2.5VA 50/60Hz
400/5A 2.5VA 2.5VA 50/60Hz
500/5A 2.5VA 5VA 50/60Hz
600/5A 2.5VA 5VA 50/60Hz
800/5A 5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
 
Product MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1.0
DP-812 500/5A / 2.5VA 50/60Hz
600/5A / 2.5VA 50/60Hz
750/5A 2.5VA 5VA 50/60Hz
800/5A 2.5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
1200/5A 5VA 10VA 50/60Hz
1500/5A 5VA 10VA 50/60Hz
1600/5A 5VA 10VA 50/60Hz
2000/5A 5VA 10VA 50/60Hz
 
Product MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1.0
DP-816 1000/5A 5VA 10VA 50/60Hz
1200/5A 7.5VA 10VA 50/60Hz
1500/5A 7.5VA 10VA 50/60Hz
1600/5A 10VA 10VA 50/60Hz
2000/5A 10VA 15VA 50/60Hz
2500/5A 10VA 20VA 50/60Hz
3000/5A 20VA 25VA 50/60Hz
4000/5A 20VA 25VA 50/60Hz
5000/5A 20VA 25VA 50/60Hz
Dimensions(mm):

 

Model A B C D E F G H I Wight(kg)
DP-23 21 31 51 89 111 34 47 40 32 0.75
DP-58 51 81 78 114 145 32 32 32 33 0.9
DP-88 81 81 108 144 145 32 32 32 33 1.05
DP-812 82 122 108 144 185 32 32 32 33 1.25
DP-816 82 162 120 184 245 52 52 52 38 4.3

Accuracy class characteristics:

Installation:

 






 
Average rating:
Share your thoughts with other customers